Low temperature flare NTV 21

C-nox environmental engineering - Contec GmbH & Co. KG

C-nox environmental engineering - Contec GmbH & Co. KG

Haberstr. 23
Neumünster, 24537
Germany
+49 4321 851990
Halle 08/08C09

Product description

A unique feature of this flare system is its operation without forced compression of the incoming biogas. The flare system only needs to burn the excess gas with a maximum reactor overpressure of 15 mbar at the digester. This is achieved through a multi-stage gas line with two-stage actuators per gas line and a burner system specifically designed for low pressure. The multi-stage design allows the system to operate within a range of approximately 1:10, thus providing the operating personnel with optimal and necessary flexibility.

The Ambarli project, along with the Atakoy project, is the second large-scale wastewater treatment plant contract in Turkey!

Technical specifications:

Maximum gas flow rate: 3.200 m³/h

Minimum gas flow rate: 400–500 m³/h

Maximum pressure: 15 mbar

CH₄ content: 65% by volume

Calorific value: 6.5 kWh/m³

Firing capacity: 20.8 MW

Gas lines: 4 x DN 150